- Voltammetric and flow amperometric determination of drug guaifenesin …
Number of the records: 1  

Voltammetric and flow amperometric determination of drug guaifenesin in pharmaceutical and biological samples using screen-printed sensor with boron doped diamond electrode

  1. Title statementVoltammetric and flow amperometric determination of drug guaifenesin in pharmaceutical and biological samples using screen-printed sensor with boron doped diamond electrode / aut. Pavlína Kelíšková, Oleksandr Matvieiev, Eliška Jiroušková, Romana Sokolová, Lenka Janíková, Miroslav Behúl, Renáta Šelešovská
    Main entry-name Kelíšková, Pavlína (Author)
    Another responsib. Matvieiev, Oleksandr (Author)
    Jiroušková, Eliška (Author)
    Sokolová, Romana (Author)
    Janíková, Lenka (Author)
    Behúl, Miroslav, 1989- Z2 (Author) - FEI Ústav elektroniky a fotoniky
    Šelešovská, Renáta (Author)
    In Talanta. -- ISSN 0039-9140. -- Vol. 281, (2025), Art. no. 126809 [10] s.
    Subj. Headings Guaifenesin
    screen-printed sensor
    boron-doped diamond electrode
    Voltammetry
    Flow injection analysis with electrochemical detection
    spectroelectrochemistry
    LanguageEnglish
    URLhttps://www.sciencedirect.com/science/article/pii/S0039914024011883?via%3Dihub
    Document kindRBX - článok z periodika
    CategoryADC - Scientific titles in foreign carented magazines and noticed year-books
    Category (from 2022)V3 - Vedecký výstup publikačnej činnosti z časopisu
    Type of documentčlánok
    In databases
    Year2025
    References (2) - článok
    article

    article

Number of the records: 1  